Working principle of lithium-thionyl chloride batteries: the Li/SOCl2 battery uses lithium as the negative electrode, carbon as the positive electrode, and a solution of anhydrous lithium tetrachloroaluminate (LiAlCl4) in SOCl2 as the electrolyte, while SOCl2 is also the positive active material. Polypropylene felt or glass fibre paper is used as the separator; the open circuit voltage is 3.65V, and the battery system can be expressed as: Li/LiAlCl4-SOCl2/C. Negative electrode: 4Li = 4Li+ + 4e; positive electrode: 2SOCl2 + 4e = 2SO2 + 4Cl-; 2SO -> (SO)2; (SO)2 -> S + sulfur dioxide. Overall battery reaction: 4Li + 2SOCl2 -> 4LiCl + S + SO2. All of the SO2 dissolves in the SOCl2, a large amount of S precipitates and deposits in the positive carbon black, and LiCl is insoluble. In such a battery, when Li contacts SOCl2 the following reaction occurs: 8Li + 4SOCl2 -> 6LiCl + Li2S2O4 + S2Cl2, or 8Li + 3SOCl2 -> 6LiCl + Li2SO3 + 2S. Because of this reaction, although the positive active material SOCl2 of the Li/SOCl2 battery closely surrounds the negative electrode, no short circuit actually occurs: the reason is that a very thin, dense LiCl protective film (the primary film) forms on the surface of the negative electrode. This film is electronically insulating but permeable to ions, which prevents further reaction between the external SOCl2 and the lithium and makes the lithium very stable in the SOCl2 electrolyte. As the ambient temperature rises and the storage time of the battery increases, the primary film gradually expands and thickens to form the so-called secondary film, and the battery consequently has a very good storage life. For this reason, the Li/SOCl2 battery also shows a relatively serious voltage delay, and because of this delay the voltage normally takes several minutes to recover to 95% of the peak voltage. For a Li/SOCl2 battery stored at 25°C for two years, the initial voltage is relatively low because of the LiCl passivation layer formed on the lithium surface; if the battery is short-circuited or repeatedly subjected to large current pulses, the LiCl film can be broken through and the working voltage restored. The products LiCl (white) and S (yellow) deposit in the positive carbon black and partly block the micro-channels in the positive electrode. On the one hand this causes the positive electrode to expand somewhat, and on the other hand it hinders the diffusion of the electrolyte, increases concentration polarisation and gradually makes the battery fail.
Requirements of the intelligent meter application environment on the high and low temperature performance of lithium thionyl chloride batteries. Through simulation tests of the temperature characteristics of lithium thionyl chloride batteries in intelligent meter applications, it was found that a high temperature environment easily causes the failure of the electrical performance of the battery and may cause leakage, explosion and other safety accidents. Therefore the temperature characteristics of the battery must be taken as an important index for assessing battery performance, including discharge performance at different temperatures, high temperature storage performance, thermal shock resistance and so on.
1 Introduction
For intelligent meters, whether electricity meters, water meters, gas meters or heat meters, batteries are needed as the real-time clock power supply, memory backup power supply or power supply.Among the many battery varieties, lithium thionyl chloride batteries have become the preferred battery variety for all kinds of intelligent meters because of their longest storage and service life, highest specific energy and widest operating temperature range (-55°C to +85°C) (specially designed and manufactured high temperature batteries can be used at up to 150°C). The temperature characteristics of a battery reflect its reliability: besides a wide operating temperature range, the battery is also required to have good resistance to high and low temperature shocks and good storage performance at high temperature. After a series of technical innovations and improvements, the temperature adaptability of MYJ brand lithium thionyl chloride batteries (lithium thionyl chloride batteries for short) has been greatly improved.
2 Requirements of the meter application environment temperature on battery temperature characteristics
2.1 High temperature environment. The ambient temperature during the use of meters varies greatly. According to user feedback, the limit temperature inside the electricity meter box hung on an outdoor utility pole can reach 80°C in summer in the south; in some Middle Eastern countries where the air temperature reaches 50°C, the temperature inside the meter box can also reach about 80°C. Therefore the temperature performance of the battery used in a meter is crucial to guaranteeing the normal operation of the intelligent meter, and the complex application environment also imposes higher requirements on the temperature performance of the battery. The temperature adaptability of the battery has thus become a particularly important index for assessing the performance of batteries used in intelligent meters. High temperature can cause internal pressure rise, volume expansion, steel case deformation and electrolyte leakage, and because the electrochemical reaction accelerates it also accelerates the internal liquid circulation and self-discharge of the battery. Considering the actual application environment, the designed upper limit of the battery operating temperature must reach 85°C; if the design temperature is too low the working life of the battery will be noticeably shortened and the working life of the meter cannot be guaranteed. This requires that the influence of high temperature on battery performance be fully studied in the battery design.2.2 Low temperature environment. In the cold regions of the north, the extreme low temperature may be below -40°C. At such low temperatures the output current and voltage of the battery both decrease because the electrochemical reaction rate drops, and the discharge capacity also decreases substantially. In addition, under extreme low and high temperature shocks the deformation of battery parts, especially the glass insulators, may be excessive, possibly causing cracks in the insulators and leakage.
2.3 Operating temperature range of MYJ lithium batteries. MYJ lithium thionyl chloride batteries improve their electrical performance in high and low temperature environments through positive electrode modification, electrolyte additives and other methods, so that the applicable temperature range of the battery can reach -55°C to +85°C. Within this range, the 10mA discharge curves of the ER14250C battery dedicated to electricity meters at different temperatures are shown in Figure 1. It can be seen from Figure 1 that good discharge results can be obtained at temperatures as low as -40°C and as high as +85°C.
4 Influence of temperature on battery safety and improvements. Developed countries in Europe and America require that all lithium batteries sold must pass UL safety certification.
The UL1642 standard is the general standard for lithium battery safety, and several of the safety performance test items are temperature related: high and low temperature cycling, thermal shock, high temperature short circuit and room temperature short circuit tests, etc. Similarly, the transport safety test certification items recommended by the United Nations (UN) also include temperature related test items such as high temperature tests, which all shows that temperature has a very important influence on the safety performance of batteries in meters. MYJ is one of the few lithium thionyl chloride battery brands in the world whose whole range has passed UL safety certification and UN transport certification. The influence of temperature on battery safety is mainly manifested as battery deformation (such as bulging bottom, swelling), leakage and explosion, which lead to meter malfunction, corrosion and instrument damage. MYJ lithium thionyl chloride batteries adopt new safety design technology and have made targeted design improvements to battery safety performance with good results. Table 1 shows the deformation and leakage of MYJ lithium thionyl chloride batteries and those of a well-known brand after storage at different high temperatures in turn. Table 1: comparison of the deformation of 1/2AA lithium thionyl chloride batteries under temperature shock. Temperature (°C) (6h storage): 80 - MYJ battery (50 pcs): no change, well-known brand battery (50 pcs): 2 pcs bulging bottom; 100 - MYJ battery (50 pcs): no change, well-known brand battery (50 pcs): 5 pcs bulging bottom, 1 pc leaking. 5 Conclusion. The temperature characteristics of lithium thionyl chloride batteries have a relatively large influence on intelligent meter applications; when an intelligent meter is used in a high temperature environment, a poorly designed battery cannot guarantee discharge performance at high temperature and may cause leakage and other safety accidents. The temperature performance of a battery has become an important factor affecting the application range of meters, and it is necessary to carefully select a battery with a suitable operating temperature range. MYJ lithium batteries have organised a dedicated research team to carry out tests and research for the applications of all kinds of intelligent meters and have accumulated considerable experience. In order to better develop the depth and breadth of the application of lithium thionyl chloride batteries in meters, we welcome meter manufacturers to discuss related issues with us.